Rev. méd. Chile ; 147(10): 1273-1282, oct. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1058594

RESUMO

Background: INR is used to monitor the treatment with vitamin K antagonists. A strategy to reduce waiting times for sampling is to measure INR in a capillary sample using a portable point of care (POC) type coagulometer. Aim: To evaluate the correlation of CoaguChek Pro II™, Xprecia™ and microINR™ with venous INR measured at the clinical laboratory and their ease of use. Materials and Methods: Patients provided capillary and venous blood samples for parallel tests comparing Xprecia™ Stride with CoaguChek Pro II™ and with venous INR, microINR™ with CoaguChek Pro IITM and with venous INR. The devices' ease of use was assessed surveying the sampling staff. Results: The three tested devices had good correlation coefficients with venous INR: CoaguChek Pro IITM 0.953 and 0.962; Xprecia™ of 0.912 and microINR™ of 0.932. The correlation coefficient of Xprecia™ with CoaguChek Pro IITM was 0.937 and microINR™ with CoaguChek Pro IITM was 0.976. Conclusions: CoaguChek Pro IITM, Xprecia™ and microINR™ results had a good correlation coefficient with INR measured at the laboratory. Our results indicate that, in the hands of trained users, POC-type coagulometers are reliable and acceptable for routine use in anticoagulant treatment control.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Sistemas Automatizados de Assistência Junto ao Leito/normas , Coeficiente Internacional Normatizado/instrumentação , Padrões de Referência , Capilares , Tromboplastina/uso terapêutico , Chile , Reprodutibilidade dos Testes , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/normas , Coeficiente Internacional Normatizado/normas , Anticoagulantes/uso terapêutico
2.
Rev Med Chil ; 147(10): 1273-1282, 2019 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-32186635

RESUMO

BACKGROUND: INR is used to monitor the treatment with vitamin K antagonists. A strategy to reduce waiting times for sampling is to measure INR in a capillary sample using a portable point of care (POC) type coagulometer. AIM: To evaluate the correlation of CoaguChek Pro II™, Xprecia™ and microINR™ with venous INR measured at the clinical laboratory and their ease of use. MATERIALS AND METHODS: Patients provided capillary and venous blood samples for parallel tests comparing Xprecia™ Stride with CoaguChek Pro II™ and with venous INR, microINR™ with CoaguChek Pro IITM and with venous INR. The devices' ease of use was assessed surveying the sampling staff. RESULTS: The three tested devices had good correlation coefficients with venous INR: CoaguChek Pro IITM 0.953 and 0.962; Xprecia™ of 0.912 and microINR™ of 0.932. The correlation coefficient of Xprecia™ with CoaguChek Pro IITM was 0.937 and microINR™ with CoaguChek Pro IITM was 0.976. CONCLUSIONS: CoaguChek Pro IITM, Xprecia™ and microINR™ results had a good correlation coefficient with INR measured at the laboratory. Our results indicate that, in the hands of trained users, POC-type coagulometers are reliable and acceptable for routine use in anticoagulant treatment control.


Assuntos
Coeficiente Internacional Normatizado/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Idoso , Anticoagulantes/uso terapêutico , Capilares , Chile , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/normas , Feminino , Humanos , Coeficiente Internacional Normatizado/normas , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Reprodutibilidade dos Testes , Tromboplastina/uso terapêutico